WA101DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA101XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA101XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA102DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA102XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA102XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA103DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA103XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA103XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA104DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA104XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA104XUDC/DC converter. UL1950 approval 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA105DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA105XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA105XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA106DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA106XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA106XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA201DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA201ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA201XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA201XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA202DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA202ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA202XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA202XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA203DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA203ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA203XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA203XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA204DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA204ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA204XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA204XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA205DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA205ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA205XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA205XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA206DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA206ADC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA206XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA206XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA301DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA301ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA301XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA301XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA302DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA302ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA302XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA302XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA303DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA303ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA303XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA303XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA304DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA304ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA304XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA304XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA305DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA305ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA305XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA305XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA306DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA306ADC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA306XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA306XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA401DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA401XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA401XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA402DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA402XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA402XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA403DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA403XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA403XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA404DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA404XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA404XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA405DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA405XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA405XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA406DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA406XDC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)
WA406XUDC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C.Datasheet*)