| WA101 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA101X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA101XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 15 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA102 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA102X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA102XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA103 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA103X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA103XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 15 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA104 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA104X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA104XU | DC/DC converter. UL1950 approval 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA105 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA105X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA105XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA106 | DC/DC converter. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 850 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA106X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA106XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 4.5-6.0 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 25 mA(no load), 800 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA201 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA201A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA201X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA201XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 7.5 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA202 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA202A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA202X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA202XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA203 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA203A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA203X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA203XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 7.5 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA204 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA204A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA204X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA204XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 12.0 mA(no load), 340 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA205 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA205A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA205X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA205XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA206 | DC/DC converter. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA206A | DC/DC converter. 4:1 input range. Input voltage 9-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA206X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA206XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 9-18 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 12.0 mA(no load), 320 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA301 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA301A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA301X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA301XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 5 VDC. Output current 500 mA. Input current 5.0 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA302 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA302A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA302X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA302XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA303 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA303A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA303X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA303XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 5.0 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA304 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA304A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA304X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA304XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 7.5 mA(no load), 168 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA305 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA305A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA305X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA305XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA306 | DC/DC converter. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA306A | DC/DC converter. 4:1 input range. Input voltage 20-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA306X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA306XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 18-36 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 7.5 mA(no load), 156 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA401 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA401X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA401XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 5 VDC. Output current 600 mA. Input current 2.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA402 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA402X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA402XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 12 VDC. Output current 250 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA403 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA403X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA403XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage 15 VDC. Output current 200 mA. Input current 2.0 mA(no load), 78 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA404 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA404X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA404XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-5 VDC. Output current +-250 mA. Input current 3.0 mA(no load), 82 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA405 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA405X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA405XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-12 VDC. Output current +-125 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA406 | DC/DC converter. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA406X | DC/DC converter. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |
| WA406XU | DC/DC converter. UL1950 approval. 3000 VDC isoladed. 2:1 input range. Input voltage 36-72 VDC. Output voltage +-15 VDC. Output current +-100 mA. Input current 3.0 mA(no load), 80 mA(full load). Operational temperature range from -25°C to 71°C. | Datasheet*) |